Title: Is There an Advantage in Designing Adapted, Patient-Specific PTV Margins in Intensity Modulated Proton Beam Therapy for Prostate Cancer?

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [2];  [1];  [3];  [1]
  1. Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University Vienna/AKH Wien (Austria)
  2. Austria
  3. Department of Radiation Oncology, Medical University of Vienna/AKH Wien (Austria)

Purpose: To investigate robust margin strategies in intensity modulated proton therapy to account for interfractional organ motion in prostate cancer. Methods and Materials: For 9 patients, one planning computed tomography (CT) scan and daily and weekly cone beam CTs (CBCTs) were acquired and coregistered. The following planning target volume (PTV) approaches were investigated: a clinical target volume (CTV) delineated on the planning CT (CTV{sub ct}) plus 10-mm margin (PTV{sub 10mm}); a reduced PTV (PTV{sub Red}): CTV{sub ct} plus 5 mm in the left-right (LR) and anterior-posterior (AP) directions and 8 mm in the inferior-superior (IS) directions; and a PTV{sub Hull} method: the sum of CTV{sub ct} and CTVs from 5 CBCTs from the first week plus 3 mm in the LR and IS directions and 5 mm in the AP direction. For each approach, separate plans were calculated using a spot-scanning technique with 2 lateral fields. Results: Each approach achieved excellent target coverage. Differences were observed in volume receiving 98% of the prescribed dose (V{sub 98%}) where PTV{sub Hull} and PTV{sub Red} results were superior to the PTV{sub 10mm} concept. The PTV{sub Hull} approach was more robust to organ motion. The V{sub 98%} for CTVs was 99.7%, whereas for PTV{sub Red} and PTV{sub 10mm} plans, V{sub 98%} was 98% and 96.1%, respectively. Doses to organs at risk were higher for PTV{sub Hull} and PTV{sub 10mm} plans than for PTV{sub Red}, but only differences between PTV{sub 10mm} and PTV{sub Red} were significant. Conclusions: In terms of organ sparing, the PTV{sub 10mm} method was inferior but not significantly different from the PTV{sub Red} and PTV{sub Hull} approaches. PTV{sub Hull} was most insensitive to target motion.

OSTI ID:
22224396
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 85, Issue 3; Other Information: Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English