Feasibility Study of Glass Dosimeter for In Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams
Journal Article
·
· International Journal of Radiation Oncology, Biology and Physics
- Department of Radiation Oncology, Myongji Hospital, Kwandong University College of Medicine, Goyang (Korea, Republic of)
- Department of Biomedical Engineering, Catholic University of Korea, Seoul (Korea, Republic of)
- Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)
- Proton Therapy Center, National Cancer Center, Goyang (Korea, Republic of)
Purpose: To evaluate the suitability of the GD-301 glass dosimeter for in vivo dose verification in proton therapy. Methods and Materials: The glass dosimeter was analyzed for its dosimetrics characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stairlike holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurements, we compared the glass dosimeter and thermoluminescent dosimeter (TLD) dose measurements using a cylindrical phantom. We investigated the feasibility of the glass dosimeter for the measurement of dose distributions near the superficial region for proton therapy plans with a varying separation between the target volume and the surface of 6 patients. Results and Discussion: Uniformity was within 1.5%. The dose-response has good linearity. Dose-rate, fading, and energy dependence were found to be within 3%. The beam profile measured using the glass dosimeter was in good agreement with the profile obtained from the ionization chamber. Depth-dose distributions in nonmodulated and modulated proton beams obtained with the glass dosimeter were estimated to be within 3%, which was lower than those with the ionization chamber. In the phantom study, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the glass dosimeter was within 5%. With in vivo dosimetry, the calculated surface doses overestimated measurements by 4%-16% using glass dosimeter and TLD. Conclusion: It is recommended that bolus be added for these clinical cases. We also believe that the glass dosimeter has considerable potential for use with in vivo patient proton dosimetry.
- OSTI ID:
- 22149547
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 2 Vol. 84; ISSN IOBPD3; ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
SU-G-TeP2-15: Feasibility Study of Fiber-Optic Cerenkov Radiation Sensors for in Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams
Evaluation of computed tomography assisted and transit dosimetry treatment planning with thermoluminescent dosimetry measurements. [4 meV photons]
Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy
Journal Article
·
Wed Jun 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:22649395
Evaluation of computed tomography assisted and transit dosimetry treatment planning with thermoluminescent dosimetry measurements. [4 meV photons]
Journal Article
·
Sun Nov 30 23:00:00 EST 1980
· Int. J. Radiat. Oncol., Biol. Phys.; (United States)
·
OSTI ID:6654649
Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy
Journal Article
·
Sat May 15 00:00:00 EDT 2010
· Medical Physics
·
OSTI ID:22100582