French Sizing of Medical Devices is not Fit for Purpose

Journal Article · · Cardiovascular and Interventional Radiology
; ;  [1];  [2];  [1]
  1. The Royal Liverpool University Hospital, Radiology Department (United Kingdom)
  2. University of Liverpool, Faculty of Health and Life Sciences (United Kingdom)

PurposeThe purpose of the study is to quantify the variation in the metric equivalent of French size in a range of medical devices, from various manufacturers, used in interventional radiology.MethodsThe labelling of a range of catheters, introducers, drains, balloons, stents, and endografts was examined. Products were chosen to achieve a broad range of French sizes from several manufacturers. To assess manufacturing accuracy, eight devices were selected for measurement using a laser micrometer. The external diameters of three specimens of each device were measured at centimeter intervals along the length of the device to ensure uniformity.ResultsA total of 200 labels of interventional radiology equipment were scrutinized. The results demonstrate a wide variation in the metric equivalent of French sizing. Labelled products can vary in diameter across the product range by up to 0.79 mm.The devices selected for measurement with the non-contact laser micrometer demonstrate acceptable manufacturing consistency. The external diameter differed by 0.05 mm on average.ConclusionsOur results demonstrate wide variation in the interpretation of the French scale by different manufacturers of medical devices. This has the potential to lead to problems using coaxial systems especially when the products are from different manufacturers. It is recommended that standard labelling should be employed by all manufacturers conveying specific details of the equipment. Given the wide variation in the interpretation of the French scale, our opinion is that this scale either needs to be abandoned or be strictly defined and followed.

OSTI ID:
22121727
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 4 Vol. 36; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

PBPK and population modelling to interpret urine cadmium concentrations of the French population
Journal Article · Mon Sep 15 00:00:00 EDT 2014 · Toxicology and Applied Pharmacology · OSTI ID:22439834

Societal risk as seen by the French public
Journal Article · Tue Jun 01 00:00:00 EDT 1993 · Risk Analysis; (United States) · OSTI ID:6479781

Custom-Made Endograft for Endovascular Repair of Thoraco-Abdominal Aneurysm and Type B Dissection: Single-Centre Experience
Journal Article · Wed Aug 15 00:00:00 EDT 2018 · Cardiovascular and Interventional Radiology · OSTI ID:22749868