Dosimetric comparison of four new design {sup 103}Pd brachytherapy sources: Optimal design using silver and copper rod cores
- Agricultural, Medical and Industrial Research School, Nuclear Science and Technology Research Institute, P.O. Box 31485-498, Karaj, Tehran (098)21 (Iran, Islamic Republic of)
Four new brachytherapy sources, IRA1-{sup 103}Pd, IRA2-{sup 103}Pd, IRA3-{sup 103}Pd, and IRA4-{sup 103}Pd, have been developed at Agricultural, Medical, and Industrial Research School and are designed for permanent implant application. With the goal of determining an optimal design for a {sup 103}Pd source, this article compares the dosimetric properties of these sources with reference to the authors' earlier IRA-{sup 103}Pd source. The four new sources differ in end cap configuration and thickness and in the core material, silver or copper, that carries the adsorbed {sup 103}Pd. Dosimetric data derived from the authors' Monte Carlo simulation results are reported in accordance with the updated AAPM Task Group No. 43 report (TG-43U1). For each source, the authors obtained detailed results for the dose rate constant {Lambda}, the radial dose function g(r), the anisotropy function F(r,{theta}), and the anisotropy factor {phi}{sub an}(r). In this study, the optimal source IRA3-{sup 103}Pd provides the most isotropic dose distribution in water with the dose rate constant of 0.678({+-}0.1%) cGy h{sup -1} U{sup -1}. The IRA3-{sup 103}Pd design has a silver rod core combined with thin-wall, concave end caps. Finally, the authors compared the results for their optimal source with published results for those of other source manufacturers.
- OSTI ID:
- 22100563
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 7 Vol. 36; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-{sup 103}Pd brachytherapy source
Dosimetric characteristics of the new RadioCoil{sup TM} {sup 103}Pd wire line source for use in permanent brachytherapy implants
{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design
Journal Article
·
Tue Apr 15 00:00:00 EDT 2008
· Medical Physics
·
OSTI ID:21120638
Dosimetric characteristics of the new RadioCoil{sup TM} {sup 103}Pd wire line source for use in permanent brachytherapy implants
Journal Article
·
Sun Oct 31 23:00:00 EST 2004
· Medical Physics
·
OSTI ID:20634432
{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design
Journal Article
·
Tue Jan 14 23:00:00 EST 2014
· Medical Physics
·
OSTI ID:22250718