Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography
- TRG Diagnostic Imaging, Bayer Schering Pharma AG, 13353 Berlin (Germany)
Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasi-monochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten K{alpha} emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement factor increases from 2.2 to 2.4 by using quasi-monochromatic instead of polychromatic radiation. An additional increase in the radiation dose by a factor of 1.4 due to the focusing characteristic of the x-ray optical module was calculated. Photoelectric-enhanced radiation therapy based on a clinical CT unit combined with an x-ray optical module is a novel therapy option in radiation oncology. The optimized quasi-monochromatic radiation is strongly focused and ensures high photoelectric dose enhancement for iodine.
- OSTI ID:
- 22100529
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 36; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Three-Dimensional Dose Verification for Intensity-Modulated Radiation Therapy in the Radiological Physics Centre Head-and-Neck Phantom Using Optical Computed Tomography Scans of Ferrous Xylenol-Orange Gel Dosimeters
Novel Multicompartment 3-Dimensional Radiochromic Radiation Dosimeters for Nanoparticle-Enhanced Radiation Therapy Dosimetry
Brain tumors and synchrotron radiation: Methodological developments in quantitative brain perfusion imaging and radiation therapy
Journal Article
·
Sat Mar 15 00:00:00 EDT 2008
· International Journal of Radiation Oncology, Biology and Physics
·
OSTI ID:21039854
Novel Multicompartment 3-Dimensional Radiochromic Radiation Dosimeters for Nanoparticle-Enhanced Radiation Therapy Dosimetry
Journal Article
·
Wed Nov 14 23:00:00 EST 2012
· International Journal of Radiation Oncology, Biology and Physics
·
OSTI ID:22149655
Brain tumors and synchrotron radiation: Methodological developments in quantitative brain perfusion imaging and radiation therapy
Journal Article
·
Thu Mar 31 23:00:00 EST 2005
· Medical Physics
·
OSTI ID:20634659
Related Subjects
61 RADIATION PROTECTION AND DOSIMETRY
62 RADIOLOGY AND NUCLEAR MEDICINE
BEAM PROFILES
COMPUTERIZED TOMOGRAPHY
DEPTH DOSE DISTRIBUTIONS
FILM DOSIMETRY
KEV RANGE 01-10
MONOCHROMATIC RADIATION
PHANTOMS
PHOTONS
POLYMER GEL DOSIMETRY
RADIATION DOSES
RADIOTHERAPY
SYNCHROTRON RADIATION
X RADIATION
X-RAY TUBES
62 RADIOLOGY AND NUCLEAR MEDICINE
BEAM PROFILES
COMPUTERIZED TOMOGRAPHY
DEPTH DOSE DISTRIBUTIONS
FILM DOSIMETRY
KEV RANGE 01-10
MONOCHROMATIC RADIATION
PHANTOMS
PHOTONS
POLYMER GEL DOSIMETRY
RADIATION DOSES
RADIOTHERAPY
SYNCHROTRON RADIATION
X RADIATION
X-RAY TUBES