Estimation of organ doses from kilovoltage cone-beam CT imaging used during radiotherapy patient position verification

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.3476459· OSTI ID:22098526
;  [1]
  1. Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States)

Purpose: The purpose of this study was to develop a practical method for estimating organ doses from kilovoltage cone-beam CT (CBCT) that can be performed with readily available phantoms and dosimeters. The accuracy of organ dose estimates made using the ImPACT patient dose calculator was also evaluated. Methods: A 100 mm pencil chamber and standard CT dose index (CTDI) phantoms were used to measure the cone-beam dose index (CBDI). A weighted CBDI (CBDI{sup w}) was then calculated from these measurements to represent the average volumetric dose in the CTDI phantom. By comparing CBDI{sup w} to the previously published organ doses, organ dose conversion coefficients were developed. The measured CBDI values were also used as inputs for the ImPACT calculator to estimate organ doses. All CBDI dose measurements were performed on both the Elekta XVI and Varian OBI at three clinically relevant locations: Head, chest, and pelvis. Results: The head, chest, and pelvis protocols yielded CBDI{sup w} values of 0.98, 16.62, and 24.13 mGy for the XVI system and 5.17, 6.14, and 21.57 mGy for the OBI system, respectively. Organ doses estimated with the ImPACT CT dose calculator showed a large range of variation from the previously measured organ doses, demonstrating its limitations for use with CBCT. Conclusions: The organ dose conversion coefficients developed in this work relate CBDI{sup w} values to organ doses previously measured using the same clinical protocols. Ultimately, these coefficients will allow for the quick estimation of organ doses from routine measurements performed using standard CTDI phantoms and pencil chambers.

OSTI ID:
22098526
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 9 Vol. 37; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

An organ and effective dose study of XVI and OBI cone‐beam CT systems
Journal Article · Sat Apr 17 00:00:00 EDT 2010 · Journal of Applied Clinical Medical Physics · OSTI ID:1524489

Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems
Journal Article · Sat Mar 15 00:00:00 EDT 2014 · Medical Physics · OSTI ID:22250980