Design of optimal collimation for dedicated molecular breast imaging systems
- Department of Radiology, Division of Nuclear Medicine, Mayo Clinic, Rochester, Minnesota 55905 (United States)
Molecular breast imaging (MBI) is a functional imaging technique that uses specialized small field-of-view gamma cameras to detect the preferential uptake of a radiotracer in breast lesions. MBI has potential to be a useful adjunct method to screening mammography for the detection of occult breast cancer. However, a current limitation of MBI is the high radiation dose (a factor of 7-10 times that of screening mammography) associated with current technology. The purpose of this study was to optimize the gamma camera collimation with the aim of improving sensitivity while retaining adequate resolution for the detection of sub-10-mm lesions. Square-hole collimators with holes matched to the pixilated cadmium zinc telluride detector elements of the MBI system were designed. Data from MBI patient studies and parameters of existing dual-head MBI systems were used to guide the range of desired collimator resolutions, source-to-collimator distances, pixel sizes, and collimator materials that were examined. General equations describing collimator performance for a conventional gamma camera were used in the design process along with several important adjustments to account for the specialized imaging geometry of the MBI system. Both theoretical calculations and a Monte Carlo model were used to measure the geometric efficiency (or sensitivity) and resolution of each designed collimator. Results showed that through optimal collimation, collimator sensitivity could be improved by factors of 1.5-3.2, while maintaining a collimator resolution of either {<=}5 or {<=}7.5 mm at a distance of 3 cm from the collimator face. These gains in collimator sensitivity permit an inversely proportional drop in the required dose to perform MBI.
- OSTI ID:
- 22098462
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 3 Vol. 36; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Collimator design for a dedicated molecular breast imaging-guided biopsy system: Proof-of-concept
Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms
Evaluation of a novel collimator for molecular breast tomosynthesis
Journal Article
·
Mon Jan 14 23:00:00 EST 2013
· Medical Physics
·
OSTI ID:22099189
Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms
Journal Article
·
Fri Jun 15 00:00:00 EDT 2012
· Medical Physics
·
OSTI ID:22098880
Evaluation of a novel collimator for molecular breast tomosynthesis
Journal Article
·
Tue Sep 05 20:00:00 EDT 2017
· Medical Physics
·
OSTI ID:1417735