Optimization of a parallel hole collimator/CdZnTe gamma-camera architecture for scintimammography
- CEA-LETI-MINATEC, F38054 Grenoble (France)
Purpose: Small field-of-view CdZnTe (CZT) gamma cameras are increasingly studied for breast lesion detection to complement mammography or ultrasonographic findings. However, in classical collimation configurations, they remain limited by the trade-off between spatial resolution and sensitivity. The HiSens architecture was proposed to overcome these limitations. Using an accurate 3D localization of the interactions inside the detector, this architecture leads to a gain in sensitivity without loss in spatial resolution. In this article, the relevance of the HiSens architecture for planar scintimammography is studied. Methods: A detective quantum efficiency (DQE) computation method is developed and used to optimize the dimensioning of a parallel hole collimator dedicated to scintimammography. Based on the DQE curves, the impact of the collimator-to-detector distance is studied. Two algorithms are proposed to combine data acquired with different collimator-to-detector distances. Results: It is shown that CZT detector virtual pixelization increases system sensitivity by 3.3 while preserving a standard LEHR spatial resolution. The introduction of a gap between the CZT detector and the collimator is useful to modulate the DQE curve shape. The combination of data acquired using different gaps in the image formation process leads to enhanced restoration of the frequency content of the images, resulting in image contrast and spatial resolution improvements. Conclusions: Acquisition duration or injected activity could be markedly reduced if the HiSens architecture with an appropriate collimator-detector gap were used.
- OSTI ID:
- 22096960
- Journal Information:
- Medical Physics, Vol. 38, Issue 4; Other Information: (c) 2011 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluation of collimation and imaging configuration in scintimammography
Optimizing Pinhole and Parallel Hole Collimation for Scintimammography With Compact Pixellated Detectors
Related Subjects
60 APPLIED LIFE SCIENCES
ALGORITHMS
BIOLOGICAL RECOVERY
BIOMEDICAL RADIOGRAPHY
COLLIMATORS
GAMMA CAMERAS
IMAGE PROCESSING
IMAGES
INTERACTIONS
MAMMARY GLANDS
OPTIMIZATION
QUANTUM EFFICIENCY
SEMICONDUCTOR MATERIALS
SENSITIVITY
SPATIAL RESOLUTION
STANDARDS