Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for a helical tomotherapy total scalp irradiation have been measured on an anthropomorphic phantom using radiochromic and radiographic film as well as a new skin dosimeter, the MOSkin. The superficial dose was found to be accurately calculated by the TomoTherapy planning system. This is in contrast to recent reports, probably due to a combination of the smaller dose grid resolution used in planning and this particular treatment primarily consisting of beamlets tangential to the scalp. The superficial dose was found to increase from 33.6 to 41.2 Gy and 36.0 to 42.0 Gy over the first 2 mm depth in the phantom in selected regions of the PTV, measured with radiochromic film. The prescription dose was 40 Gy. The superficial dose was at the prescription dose or higher in some regions due to the bolus effect of the thermoplastic head mask and the head rest used to aid treatment setup. It is suggested that to achieve the prescription dose at the surface ({<=}2 mm depth) bolus or a custom thermoplastic helmet is used.
OSTI ID:
22095255
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 11 Vol. 35; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Helical tomotherapy superficial dose measurements
Journal Article · Wed Aug 15 00:00:00 EDT 2007 · Medical Physics · OSTI ID:20953505

Total scalp irradiation using helical tomotherapy
Journal Article · Fri Sep 30 00:00:00 EDT 2005 · Medical Dosimetry · OSTI ID:20696222

Bolus-dependent dosimetric effect of positioning errors for tangential scalp radiotherapy with helical tomotherapy
Journal Article · Tue Apr 01 00:00:00 EDT 2014 · Medical Dosimetry · OSTI ID:22267976