skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A Comprehensive Analysis of Cardiac Dose in Balloon-Based High-Dose-Rate Brachytherapy for Left-Sided Breast Cancer

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1]; ; ;  [1]
  1. Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, PA (United States)

Purpose: To investigate radiation dose to the heart in 60 patients with left-sided breast cancer who were treated with balloon-based high-dose-rate brachytherapy using MammoSite or Contura applicators. Methods and Materials: We studied 60 consecutive women with breast cancer who were treated with 34 Gy in 10 twice-daily fractions using MammoSite (n = 37) or Contura (n = 23) applicators. The whole heart and the left and right ventricles were retrospectively delineated, and dose-volume histograms were analyzed. Multiple dosimetrics were reported, such as mean dose (D{sub mean}); relative volume receiving 1.7, 5, 10, and 20 Gy (V1.7, V5, V10, and V20, respectively); dose to 1 cc (D{sub 1cc}); and maximum point dose (D{sub max}). Biologic metrics, biologically effective dose and generalized equivalent uniform dose were computed. The impact of lumpectomy cavity location on cardiac dose was investigated. Results: The average {+-} standard deviation of D{sub mean} was 2.45 {+-} 0.94 Gy (range, 0.56-4.68) and 3.29 {+-} 1.28 Gy (range, 0.77-6.35) for the heart and the ventricles, respectively. The average whole heart V5 and V10 values were 10.2% and 1.3%, respectively, and the heart D{sub max} was >20 Gy in 7 of 60 (11.7%) patients and >25 Gy in 3 of 60 (5%) patients. No cardiac tissue received {>=}30 Gy. The V1.7, V5, V10, V20, and D{sub mean} values were all higher for the ventricles than for the whole heart. For balloons located in the upper inner quadrant of the breast, the average whole heart D{sub mean} was highest. The D{sub mean}, biologically effective dose, and generalized equivalent uniform dose values for heart and ventricles decreased with increasing minimal distance from the surface of the balloon. Conclusions: On the basis of these comprehensive cardiac dosimetric data, we recommend that cardiac dose be routinely reported and kept as low as possible in balloon-based high-dose-rate brachytherapy treatment planning for patients with left-sided breast cancer so the correlation with future cardiac toxicity data can be investigated.

OSTI ID:
22056215
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 82, Issue 5; Other Information: Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English