Experimental Studies and Energy Modeling for Evaluating Performance of Various Deep Wall Retrofits

Conference ·
OSTI ID:2202441
The Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota conducted a three-year, multipart study on residential retrofit wall assemblies. The project, which was funded by the U.S. Department of Energy’s Building Technology Office, aimed to compare a range of residential wall retrofit systems that prioritized affordability, durability, and energy savings potential. The research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations) that can be applied to the exterior side of existing walls (either with or without the existing cladding). The 16 wall assemblies were installed in an in-situ laboratory environment, to evaluate the ease of construction and study the thermal and hygrothermal performance of the walls. This paper presents the methodology used to evaluate the thermal performance of the walls and discusses the energy modeling results of the study. The results from the experiments were used to calibrate a THERM model of each wall assembly, which was then applied to a whole building using the EnergyPlus 8.6 simulation engine. A residential prototype building was used to extrapolate whole-building energy savings in each U.S. climate zone. To capture the conditions of the largest number of homes in the United States, the most frequent building characteristics (e.g., attic insulation level, window specifications, foundation insulation, etc.) were extracted from ResStock data and applied to the prototype model. Results from the energy modeling showed that the climate zones with the highest potential for retrofit savings are those which are heating-dominated (i.e., Cold and Very Cold climate designations). In these climate zones, heating and cooling energy savings due to the wall retrofits alone ranged from 21.5% to 38.2%.
Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
2202441
Report Number(s):
PNNL-SA-171684
Country of Publication:
United States
Language:
English

Similar Records

Wall Upgrades for Deep Energy Savings in Residential Buildings: Interim Results from a Multi-Year Study
Conference · Wed Sep 30 00:00:00 EDT 2020 · OSTI ID:1736004

Assessing the Performance, Application, and Cost of Retrofit Wall Systems for Residential Buildings
Conference · Mon Feb 28 23:00:00 EST 2022 · OSTI ID:1872860

Wall Upgrades for Residential Deep Energy Retrofits: Expert Meeting Report
Technical Report · Sat Jun 01 00:00:00 EDT 2019 · OSTI ID:1544552

Related Subjects