Product Consistency Test Results for the HLW HAlG Glasses

Technical Report ·
DOI:https://doi.org/10.2172/2202407· OSTI ID:2202407
 [1]
  1. Savannah River National Laboratory (SRNL), Aiken, SC (United States)
This report summarizes the chemical analysis of Product Consistency Test leachates received from Pacific Northwest National Laboratory (PNNL). The leachates are from a series of quenched simulated nuclear waste glasses designated High-Level Waste High Aluminum Glass that were designed and fabricated at PNNL. The reported data is provided to be used in the development, validation, and implementation of enhanced property/composition models for waste glass vitrification at Hanford. The elemental release for the study glasses is reported as normalized concentration NCi. NCi of several elements was computed for both the target and measured glass compositions. Several of the glasses exhibited NCB, NCLi, and/or NCNa values that were greater than the Environmental Assessment (EA) benchmark values. Several of the leachates from approved reference material (ARM) glasses included with the study glasses had elemental concentrations greater than the expected ranges. Two water blanks contained measurable amounts of Si; measurements confirmed by rerun samples. One water blank also contained a measurable amount of Na.
Research Organization:
Savannah River National Laboratory (SRNL), Aiken, SC (United States)
Sponsoring Organization:
USDOE Office of Environmental Management (EM)
DOE Contract Number:
89303321CEM000080
OSTI ID:
2202407
Report Number(s):
SRNL--STI-2022-00659
Country of Publication:
United States
Language:
English

Similar Records

Product Consistency Test Results for the LAW ML1 Glasses
Technical Report · Sat Jul 01 00:00:00 EDT 2023 · OSTI ID:1993031

Product Consistency Test Results for the LAW HPVR Glasses
Technical Report · Tue Feb 28 23:00:00 EST 2023 · OSTI ID:1969070

Product Consistency Test Results for the LAW Phase 5 Rerun Leachates
Technical Report · Sat Jul 01 00:00:00 EDT 2023 · OSTI ID:1993036