Design and Overview of 100 kV Bushing for the DNB Injector of ITER
- ITER-India, Institute for Plasma Research, Gandhinagar-382025, Gujarat (India)
- DesignTech Systems Ltd, Banjara Hills, Hyderabad, Andhra Pradesh-500034 (India)
- ITER Organisation, Route de Vinon, CS 90 046, 13067 St. Paul lez Durance Cedex (France)
The 100 kV bushing is one of the most important and technologically challenging Safety Important Class (SIC) components of the Diagnostic Neutral Beam (DNB) injector of ITER. It forms interface between gas insulated electrical transmission line and torus primary vacuum and acts as a vacuum feedthrough of ITER. Design optimization has been carried out to meet the electric and structural requirements based on its classification. Unlike HNB bushing, single stage bushing is designed to provide 100 kV isolation. Finite Element Analysis (FEA) based optimization has been carried out for electrostatic and structural analysis. Manufacturing assembly sequence is studied and presented in this paper. However validation of the same is foreseen from manufacturer.
- OSTI ID:
- 21611702
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 1390; ISSN APCPCS; ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Status of the Negative Ion Based Heating and Diagnostic Neutral Beams for ITER
Negative Ion Based Heating and Diagnostic Neutral Beams for ITER
Related Subjects
70 PLASMA PHYSICS AND FUSION TECHNOLOGY
BEAM INJECTION
BEAM INJECTION HEATING
CALCULATION METHODS
CLOSED PLASMA DEVICES
DESIGN
ELECTROSTATICS
FINITE ELEMENT METHOD
HEATING
ITER TOKAMAK
MATHEMATICAL SOLUTIONS
NEUTRAL ATOM BEAM INJECTION
NUMERICAL SOLUTION
OPTIMIZATION
PLASMA BEAM INJECTION
PLASMA HEATING
POWER TRANSMISSION LINES
THERMONUCLEAR DEVICES
THERMONUCLEAR REACTORS
TOKAMAK DEVICES
TOKAMAK TYPE REACTORS