skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A Novel Mechanical Thrombectomy Device for Retrieval of Intravascular Thrombus

Journal Article · · Cardiovascular and Interventional Radiology
 [1];  [2];  [3];  [2];  [3]
  1. University of Thessaloniki, Department of Diagnostic and Interventional Neuroradiology (Greece)
  2. NexGen Medical Systems Inc. (United States)
  3. University of California Davis Medical Center, Department of Radiology (United States)

Purpose: Thrombotic and embolic vascular occlusion represents a leading cause of morbidity and mortality. Currently available thrombectomy devices have limitations, including difficulty removing organized thrombus and clot fragmentation with distal embolization. A novel mechanical thrombectomy device (MTD), designed to remove both hard and soft thrombus without trauma to the blood vessel, was tested in preclinical porcine models evaluating efficacy, safety, and ease of use. Materials and Methods: A total of 26 vessels in 14 pigs underwent mechanical thrombectomy with MTD. Thrombectomy was performed in nine superficial femoral arteries, eight subclavian arteries, five primary branches of the subclavian artery, lateral thoracic artery or the thyrocervical trunk, and four external carotids. Subacute organized fibrin-laden thrombus was injected into the arteries producing vascular occlusion. The MTD was then used for thrombectomy to restore patency and blood flow. Results: Intact thrombus was retrieved from 24 of 26 of the vessels with a single pass of the MTD, resulting in complete restoration of patency in 21 vessels and partial patency in 4 vessels. In 8 cases that used an early design, the embolic material fragmented during withdrawal from the access sheath. In 4 procedures that used an early design, the MTD failed to deploy fully and the embolus was not completely captured. No intraprocedural complications or vascular damage occurred. Conclusions: The present pilot studies demonstrate basic safety and efficacy of a novel MTD with design attributes suitable for retrieval of intact acute and organized chronic thrombus. The device has potential intracranial and peripheral utility.

OSTI ID:
21608731
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 34, Issue 2; Other Information: DOI: 10.1007/s00270-010-0024-7; Copyright (c) 2011 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Article Copyright (c) 2010 The Author(s); Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English