Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy

Journal Article · · Cardiovascular and Interventional Radiology
;  [1];  [2];  [3];  [4]; ; ; ; ; ; ;  [2]
  1. University of California Davis Medical School (United States)
  2. University of California Davis Medical Center, Department of Radiology (United States)
  3. University of California Davis, Department of Statistics (United States)
  4. University of California Davis, Division of Biostatistics, Department of Public Health Services (United States)

Purpose: The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. Methods: Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Three observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. Results: Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan-Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). Conclusion: Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival.

OSTI ID:
21608714
Journal Information:
Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 2 Vol. 34; ISSN 0174-1551; ISSN CAIRDG
Country of Publication:
United States
Language:
English

Similar Records

Changes in Normal Liver and Spleen Volume after Radioembolization with {sup 90}Y-Resin Microspheres in Metastatic Breast Cancer Patients: Findings and Clinical Significance
Journal Article · Sat Oct 15 00:00:00 EDT 2011 · Cardiovascular and Interventional Radiology · OSTI ID:21608588

Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?
Journal Article · Tue Mar 15 00:00:00 EDT 2016 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22645135

Prospective Study Validating Inter- and Intraobserver Variability of Tissue Compliance Meter in Breast Tissue of Healthy Volunteers: Potential Implications for Patients With Radiation-Induced Fibrosis of the Breast
Journal Article · Sun May 01 00:00:00 EDT 2011 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21491719