Paget-Schroetter Syndrome Treated with Cutting-Balloon Angioplasty
Journal Article
·
· Cardiovascular and Interventional Radiology
- University Hospital of North Staffordshire NHS Trust, Department of Interventional Radiology, City General Hospital (United Kingdom)
Here, a case of Paget-Schroetter Syndrome in a 25-year-old guitar player is reported. After thrombolysis, conventional angioplasty failed to dilate the underlying subclavian stenosis both before and after first-rib excision with scalenus anterior and medius division. For the third attempt at angioplasty, a cutting balloon was used, which immediately produced a good result. Venography at 4-year follow-up showed no restenosis and no functional deficit. This case report demonstrates that cutting-balloon angioplasty may be considered when conventional balloon fails and may have greater durability than conventional balloon angioplasty in the treatment of Paget-Schroetter syndrome.
- OSTI ID:
- 21608517
- Journal Information:
- Cardiovascular and Interventional Radiology, Vol. 35, Issue 3; Other Information: DOI: 10.1007/s00270-011-0245-4; Copyright (c) 2012 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
- Country of Publication:
- United States
- Language:
- English
Similar Records
Pharmacomechanical Thrombectomy in Paget–Schroetter Syndrome
Angioplasty for Non-arteriosclerotic Renal Artery Stenosis: The Efficacy of Cutting Balloon Angioplasty Versus Conventional Angioplasty
Restoration of Failed Renal Graft Function After Successful Angioplasty of Pressure-Resistant Renal Artery Stenosis Using a Cutting Balloon: A Case Report
Journal Article
·
Thu Sep 15 00:00:00 EDT 2016
· Cardiovascular and Interventional Radiology
·
OSTI ID:21608517
+4 more
Angioplasty for Non-arteriosclerotic Renal Artery Stenosis: The Efficacy of Cutting Balloon Angioplasty Versus Conventional Angioplasty
Journal Article
·
Sun Jul 15 00:00:00 EDT 2007
· Cardiovascular and Interventional Radiology
·
OSTI ID:21608517
Restoration of Failed Renal Graft Function After Successful Angioplasty of Pressure-Resistant Renal Artery Stenosis Using a Cutting Balloon: A Case Report
Journal Article
·
Fri May 15 00:00:00 EDT 2009
· Cardiovascular and Interventional Radiology
·
OSTI ID:21608517