Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions
Journal Article
·
· AIP Conference Proceedings
- Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 Distrito Federal (Mexico)
- Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Distrito Federal (Mexico)
- Hospital Infantil de Mexico 'Federico Gomez', Distrito Federal (Mexico)
Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used was a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.
- OSTI ID:
- 21506979
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 1310; ISSN APCPCS; ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Dosimetry and Image Quality in Control Studies in Computerised Tomography Realized to Paediatric Patients
Reference dosimetry during diagnostic CT examination using XR-QA radiochromic film model
Pediatric Computed Tomography. Radiation Dose in Abdominal Studies
Journal Article
·
Mon Aug 11 00:00:00 EDT 2008
· AIP Conference Proceedings
·
OSTI ID:21149261
Reference dosimetry during diagnostic CT examination using XR-QA radiochromic film model
Journal Article
·
Thu Sep 15 00:00:00 EDT 2011
· Medical Physics
·
OSTI ID:22098616
Pediatric Computed Tomography. Radiation Dose in Abdominal Studies
Journal Article
·
Mon Aug 11 00:00:00 EDT 2008
· AIP Conference Proceedings
·
OSTI ID:21149267
Related Subjects
62 RADIOLOGY AND NUCLEAR MEDICINE
BODY
BUILDINGS
CALCULATION METHODS
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
DOSES
ELECTRIC MEASURING INSTRUMENTS
ELECTRICAL EQUIPMENT
ELECTROMAGNETIC RADIATION
ELECTROMETERS
EQUIPMENT
HOSPITALS
INDUSTRY
IONIZATION CHAMBERS
IONIZING RADIATIONS
LUNGS
MEASURING INSTRUMENTS
MEDICAL ESTABLISHMENTS
MOCKUP
MONTE CARLO METHOD
NUCLEAR INDUSTRY
ORGANS
PATIENTS
PHANTOMS
RADIATION DETECTORS
RADIATION DOSES
RADIATIONS
RESPIRATORY SYSTEM
STRUCTURAL MODELS
TOMOGRAPHY
X RADIATION
BODY
BUILDINGS
CALCULATION METHODS
COMPUTERIZED TOMOGRAPHY
DIAGNOSTIC TECHNIQUES
DOSES
ELECTRIC MEASURING INSTRUMENTS
ELECTRICAL EQUIPMENT
ELECTROMAGNETIC RADIATION
ELECTROMETERS
EQUIPMENT
HOSPITALS
INDUSTRY
IONIZATION CHAMBERS
IONIZING RADIATIONS
LUNGS
MEASURING INSTRUMENTS
MEDICAL ESTABLISHMENTS
MOCKUP
MONTE CARLO METHOD
NUCLEAR INDUSTRY
ORGANS
PATIENTS
PHANTOMS
RADIATION DETECTORS
RADIATION DOSES
RADIATIONS
RESPIRATORY SYSTEM
STRUCTURAL MODELS
TOMOGRAPHY
X RADIATION