Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Dosimetric Comparison of Helical Tomotherapy and Linac-IMRT Treatment Plans for Head and Neck Cancer Patients

Journal Article · · Medical Dosimetry
; ; ; ;  [1]
  1. Department of Radiation Oncology, College of Medicine, University of Arkansas, Little Rock (United States)

The rapid development and clinical implementation of external beam radiation treatment technologies continues. The existence of various commercially available technologies for intensity-modulated radiation therapy (IMRT) has stimulated interest in exploring the differential potential advantage one may have compared with another. Two such technologies, Hi-Art Helical Tomotherapy (HT) and conventional medical linear accelerator-based IMRT (LIMRT) have been shown to be particularly suitable for the treatment of head and neck cancers. In this study, 23 patients who were diagnosed with stages 3 or 4 head and neck cancers, without evidence of distance metastatic disease, were treated in our clinic. Treatment plans were developed for all patients simultaneously on the HT planning station and on the Pinnacle treatment planning system for step-and-shoot IMRT. Patients were treated only on the HT unit, with the LIMRT plan serving as a backup in case the HT system might not be available. All plans were approved for clinical use by a physician. The prescription was that patients receive at least 95% of the planning target volume (PTV), which is 66 Gy at 2.2 Gy per fraction. Several dosimetric parameters were computed: PTV dose coverage; PTV volume conformity index; the normalized total dose (NTD), where doses were converted to 2 Gy per fraction to organs at risk (OAR); and PTV dose homogeneity. Both planning systems satisfied our clinic's PTV prescription requirements. The results suggest that HT plans had, in general, slightly better dosimetric characteristics, especially regarding PTV dose homogeneity and normal tissue sparing. However, for both techniques, doses to OAR were well below the currently accepted normal tissue tolerances. Consequently, factors other than the dosimetric parameters studied here may have to be considered when making a choice between IMRT techniques.

OSTI ID:
21486868
Journal Information:
Medical Dosimetry, Journal Name: Medical Dosimetry Journal Issue: 4 Vol. 35; ISSN 0958-3947
Country of Publication:
United States
Language:
English

Similar Records

Comparison of IMRT Treatment Plans Between Linac and Helical Tomotherapy Based on Integral Dose and Inhomogeneity Index
Journal Article · Wed Oct 01 00:00:00 EDT 2008 · Medical Dosimetry · OSTI ID:21140789

Helical Tomotherapy of Nasopharyngeal Carcinoma-Any Advantages Over Conventional Intensity-Modulated Radiotherapy?
Journal Article · Thu Jul 01 00:00:00 EDT 2010 · Medical Dosimetry · OSTI ID:21333979

Helical Tomotherapy for Parotid Gland Tumors
Journal Article · Fri Feb 29 23:00:00 EST 2008 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21039804