Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Parameters of an electric-discharge generator of iodine atoms for a chemical oxygen-iodine laser

Journal Article · · Quantum Electronics (Woodbury, N.Y.)
; ; ; ; ;  [1]
  1. Samara Branch of the P.N. Lebedev Physics Institute, Russian Academy of Sciences, Samara (Russian Federation)
Laser-induced fluorescence is used for measuring the concentration of iodine molecules at the output of an electric-discharge generator of atomic iodine. Methyl iodide CH{sub 3}I is used as the donor of atomic iodine. The fraction of iodine extracted from CH{sub 3}I in the generator is {approx}50%. The optimal operation regimes are found in which 80%-90% of iodine contained in the output flow of the generator was in the atomic state. This fraction decreased during the iodine transport due to recombination and was 20%-30% at the place where iodine was injected into the oxygen flow. The fraction of the discharge power spent for dissociation was {approx}3%. (elements of laser setups)
OSTI ID:
21476066
Journal Information:
Quantum Electronics (Woodbury, N.Y.), Journal Name: Quantum Electronics (Woodbury, N.Y.) Journal Issue: 1 Vol. 39; ISSN 1063-7818
Country of Publication:
United States
Language:
English