skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Biocompatibility and Recanalization Characteristics of Hydrogel Microspheres with Polyzene-F as Polymer Coating

Journal Article · · Cardiovascular and Interventional Radiology
; ; ; ; ; ;  [1];  [2];
  1. University of Heidelberg Medical Center, Department of Diagnostic Radiology (Germany)
  2. University of Heidelberg Medical Center, Department of Pathology (Germany)

The objective of this study was to evaluate inflammatory response and recanalization after embolization with a new spherical embolic agent based on a core and shell design with a hydrogel core of polymethylmethacrylate (PMMA) and a Polyzene-F nanoscale coating in a porcine kidney model. Thirty-six minipigs were enrolled for superselective renal embolization. Polyzene-F-coated PMMA particles and uncoated PMMA particles with a diameter of 300-600 {mu}m were used. Either 4 or 12 weeks post-embolization, arteriography of the embolized kidneys was performed and then compared with pre- and immediate post-embolization arteriograms using a specific recanalization score to determine the extent of recanalization. Using a microscopic inflammation score (Banff classification), the embolized organs were examined for local inflammatory effects which occurred in response to the embolic agent. In Polyzene-F-coated particles, the Banff classification showed an average inflammation score of 0.26 {+-} 0.58 at 4 weeks and of 0.08 {+-} 0.28 at 12 weeks. In uncoated particles, the Banff score measured 0.37 {+-} 0.6 at 4 weeks, which was higher, but without a statistically significant difference. According to the recanalization score used in this study, mild angiographic recanalization was evident in all groups, without statistically significant differences (3.0 {+-} 0.71 in coated particles, 3.09 {+-} 0.81 in uncoated particles; p = 0.74). We conclude that both uncoated hydrogel particles and Polyzene-F-coated embolic agents triggered virtually no inflammatory response and effectively occluded target arteries. This study demonstrates good biocompatibility of the new embolic material. As in other spherical embolic agents, recanalization can occur to some degree.

OSTI ID:
21450369
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 31, Issue 4; Other Information: DOI: 10.1007/s00270-007-9268-2; Copyright (c) 2008 Springer Science+Business Media, LLC; ISSN 0174-1551
Country of Publication:
United States
Language:
English