Dose Gradient Near Target-Normal Structure Interface for Nonisocentric CyberKnife and Isocentric Intensity-Modulated Body Radiotherapy for Prostate Cancer
Journal Article
·
· International Journal of Radiation Oncology, Biology and Physics
- Department of Radiation Oncology, University of California, San Francisco, School of Medicine, San Francisco, CA (United States)
Purpose: The treatment planning quality between nonisocentric CyberKnife (CK) and isocentric intensity modulation treatment was studied for hypofractionated prostate body radiotherapy. In particular, the dose gradient across the target and the critical structures such as the rectum and bladder was characterized. Methods and Materials: In the present study, patients treated with CK underwent repeat planning for nine fixed-field intensity-modulated radiotherapy (IMRT) using identical contour sets and dose-volume constraints. To calculate the dose falloff, the clinical target volume contours were expanded 30 mm anteriorly and posteriorly and 50 mm uniformly in other directions for all patients in the CK and IMRT plans. Results: We found that all the plans satisfied the dose-volume constraints, with the CK plans showing significantly better conformity than the IMRT plans at a relative greater dose inhomogeneity. The rectal and bladder volumes receiving a low dose were also lower for CK than for IMRT. The average conformity index, the ratio of the prescription isodose volume and clinical target volume, was 1.18 {+-} 0.08 for the CK plans vs. 1.44 {+-} 0.11 for the IMRT plans. The average homogeneity index, the ratio of the maximal dose and the prescribed dose to the clinical target volume, was 1.45 {+-} 0.12 for the CK plans vs. 1.28 {+-} 0.06 for the IMRT plans. The average percentage of dose falloff was 2.9% {+-} 0.8%/mm for CK and 3.1% {+-} 1.0%/mm for IMRT in the anterior direction, 3.8% {+-} 1.6%/mm for CK and 3.2% {+-} 1.9%/mm for IMRT in the posterior direction, and 3.6% {+-} 0.4% for CK and 3.6% {+-} 0.4% for IMRT in all directions. Conclusion: Nonisocentric CK was as capable of producing equivalent fast dose falloff as high-number fixed-field IMRT delivery.
- OSTI ID:
- 21436141
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 1 Vol. 78; ISSN IOBPD3; ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
Virtual HDR{sup SM} CyberKnife Treatment for Localized Prostatic Carcinoma: Dosimetry Comparison With HDR Brachytherapy and Preliminary Clinical Observations
SU-E-T-355: A Comparative Study of Robotic and Linac-Based Stereotactitc Body Radiation Therapy for Lumbar Spinal Tumors
SU-F-T-601: Equivalence of CyberKnife and TrueBeam STx for Spine Irradiation
Journal Article
·
Tue Apr 01 00:00:00 EDT 2008
· International Journal of Radiation Oncology, Biology and Physics
·
OSTI ID:21124171
SU-E-T-355: A Comparative Study of Robotic and Linac-Based Stereotactitc Body Radiation Therapy for Lumbar Spinal Tumors
Journal Article
·
Sun Jun 01 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22355902
SU-F-T-601: Equivalence of CyberKnife and TrueBeam STx for Spine Irradiation
Journal Article
·
Wed Jun 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:22649171
Related Subjects
62 RADIOLOGY AND NUCLEAR MEDICINE
BLADDER
BODY
DIGESTIVE SYSTEM
DISEASES
DOSES
FRACTIONATED IRRADIATION
GASTROINTESTINAL TRACT
GLANDS
INTERFACES
INTESTINES
IRRADIATION
LARGE INTESTINE
MALE GENITALS
MEDICINE
NEOPLASMS
NUCLEAR MEDICINE
ORGANS
PROSTATE
RADIATION DOSES
RADIOLOGY
RADIOTHERAPY
RECTUM
THERAPY
URINARY TRACT
BLADDER
BODY
DIGESTIVE SYSTEM
DISEASES
DOSES
FRACTIONATED IRRADIATION
GASTROINTESTINAL TRACT
GLANDS
INTERFACES
INTESTINES
IRRADIATION
LARGE INTESTINE
MALE GENITALS
MEDICINE
NEOPLASMS
NUCLEAR MEDICINE
ORGANS
PROSTATE
RADIATION DOSES
RADIOLOGY
RADIOTHERAPY
RECTUM
THERAPY
URINARY TRACT