Whole-Body Magnetic Resonance Angiography with Additional Steady-State Acquisition of the Infragenicular Arteries in Patients with Peripheral Arterial Disease
Journal Article
·
· Cardiovascular and Interventional Radiology
- Rigshospitalet, Department of Vascular Surgery (Denmark)
- University Hospital at Herlev, Department of Radiology (Denmark)
- University Hospital at Gentofte, Department of Radiology (Denmark)
The purpose of this investigation was to determine if addition of infragenicular steady-state (SS) magnetic resonance angiography (MRA) to first-pass imaging improves diagnostic performance compared with first-pass imaging alone in patients with peripheral arterial disease (PAD) undergoing whole-body (WB) MRA. Twenty consecutive patients with PAD referred to digital-subtraction angiography (DSA) underwent WB-MRA. Using a bolus-chase technique, first-pass WB-MRA was performed from the supra-aortic vessels to the ankles. The blood-pool contrast agent gadofosveset trisodium was used at a dose of 0.03 mmol/kg body weight. Ten minutes after injection of the contrast agent, high-resolution (0.7-mm isotropic voxels) SS-MRA of the infragenicular arteries was performed. Using DSA as the 'gold standard,' sensitivities and specificities for detecting significant arterial stenoses ({>=}50% luminal narrowing) with first-pass WB-MRA, SS-MRA, and combined first-pass and SS-MRA were calculated. Kappa statistics were used to determine intermodality agreement between MRA and DSA. Overall sensitivity and specificity for detecting significant arterial stenoses with first-pass WB-MRA was 0.70 (95% confidence interval 0.61 to 0.78) and 0.97 (0.94 to 0.99), respectively. In first-pass WB-MRA, the lowest sensitivity was in the infragenicular region, with a value of 0.42 (0.23 to 0.63). Combined analysis of first-pass WB-MRA and SS-MRA increased sensitivity to 0.81 (0.60 to 0.93) in the infragenicular region, with specificity of 0.94 (0.88 to 0.97). Sensitivity and specificity for detecting significant arterial stenoses with isolated infragenicular SS-MRA was 0.47 (0.27 to 0.69) and 0.86 (0.78 to 0.91), respectively. Intermodality agreement between MRA and DSA in the infragenicular region was moderate for first-pass WB-MRA ({kappa} = 0.49), fair for SS-MRA ({kappa} = 0.31), and good for combined first-pass/SS-MRA ({kappa} = 0.71). Addition of infragenicular SS-MRA to first-pass WB MRA improves diagnostic performance.
- OSTI ID:
- 21428983
- Journal Information:
- Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 3 Vol. 33; ISSN 0174-1551; ISSN CAIRDG
- Country of Publication:
- United States
- Language:
- English
Similar Records
Whole-Body Magnetic Resonance Angiography at 3 Tesla Using a Hybrid Protocol in Patients with Peripheral Arterial Disease
Review of Source Images is Necessary for the Evaluation of Gadolinium-Enhanced MR Angiography for Renal Artery Stenosis
Routine Use of Three-Dimensional Contrast-Enhanced Moving-Table MR Angiography in Patients with Peripheral Arterial Occlusive Disease: Comparison with Selective Digital Subtraction Angiography
Journal Article
·
Tue Sep 15 00:00:00 EDT 2009
· Cardiovascular and Interventional Radiology
·
OSTI ID:21429118
Review of Source Images is Necessary for the Evaluation of Gadolinium-Enhanced MR Angiography for Renal Artery Stenosis
Journal Article
·
Wed Sep 15 00:00:00 EDT 2004
· Cardiovascular and Interventional Radiology
·
OSTI ID:21088207
Routine Use of Three-Dimensional Contrast-Enhanced Moving-Table MR Angiography in Patients with Peripheral Arterial Occlusive Disease: Comparison with Selective Digital Subtraction Angiography
Journal Article
·
Sun Oct 15 00:00:00 EDT 2006
· Cardiovascular and Interventional Radiology
·
OSTI ID:21091154