Uterine Artery Embolization for Leiomyomata: Optimization of the Radiation Dose to the Patient Using a Flat-Panel Detector Angiographic Suite
- Georges Pompidou European Hospital, Department of Cardio Vascular Radiology (France)
- Institute for Radiological Protection and Nuclear Safety (IRSN) (France)
The purpose of this study was to assess the ability of low-dose/low-frame fluoroscopy/angiography with a flat-panel detector angiographic suite to reduce the dose delivered to patients during uterine fibroid embolization (UFE). A two-step prospective dosimetric study was conducted, with a flat-panel detector angiography suite (Siemens Axiom Artis) integrating automatic exposure control (AEC), during 20 consecutive UFEs. Patient dosimetry was performed using calibrated thermoluminescent dosimeters placed on the lower posterior pelvis skin. The first step (10 patients; group A) consisted in UFE (bilateral embolization, calibrated microspheres) performed using the following parameters: standard fluoroscopy (15 pulses/s) and angiography (3 frames/s). The second step (next consecutive 10 patients; group B) used low-dose/low-frame fluoroscopy (7.5 pulses/s for catheterization and 3 pulses/s for embolization) and angiography (1 frame/s). We also recorded the total dose-area product (DAP) delivered to the patient and the fluoroscopy time as reported by the manufacturer's dosimetry report. The mean peak skin dose decreased from 2.4 {+-} 1.3 to 0.4 {+-} 0.3 Gy (P = 0.001) for groups A and B, respectively. The DAP values decreased from 43,113 {+-} 27,207 {mu}Gy m{sup 2} for group A to 9,515 {+-} 4,520 {mu}Gy m{sup 2} for group B (P = 0.003). The dose to ovaries and uterus decreased from 378 {+-} 238 mGy (group A) to 83 {+-} 41 mGy (group B) and from 388 {+-} 246 mGy (group A) to 85 {+-} 39 mGy (group B), respectively. Effective doses decreased from 112 {+-} 71 mSv (group A) to 24 {+-} 12 mSv (group B) (P = 0.003). In conclusion, the use of low-dose/low-frame fluoroscopy/angiography, based on a good understanding of the AEC system and also on the technique during uterine fibroid embolization, allows a significant decrease in the dose exposure to the patient.
- OSTI ID:
- 21428925
- Journal Information:
- Cardiovascular and Interventional Radiology, Vol. 33, Issue 5; Other Information: DOI: 10.1007/s00270-010-9795-0; Copyright (c) 2010 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); ISSN 0174-1551
- Country of Publication:
- United States
- Language:
- English
Similar Records
Radiation Exposure During Uterine Artery Embolization: Effective Measures to Minimize Dose to the Patient
Normalized dose data for upper gastrointestinal tract contrast studies performed to infants
Related Subjects
ARTERIES
DOSIMETRY
EMBOLI
FLUOROSCOPY
OPTIMIZATION
OVARIES
PATIENTS
PELVIS
RADIATION DOSES
SKIN
THERMOLUMINESCENT DOSEMETERS
UTERUS
BIOMEDICAL RADIOGRAPHY
BLOOD VESSELS
BODY
CARDIOVASCULAR SYSTEM
DIAGNOSTIC TECHNIQUES
DOSEMETERS
DOSES
FEMALE GENITALS
GONADS
LUMINESCENT DOSEMETERS
MEASURING INSTRUMENTS
MEDICINE
NUCLEAR MEDICINE
ORGANS
RADIOLOGY