Title: Percutaneous embolization of a high-flow pancreatic transplant arteriovenous fistula

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/BF03035357· OSTI ID:21414392
;  [1];  [2]; ;  [1];  [2]
  1. University of Virginia, Health Science Center, Department of Radiology (United States)
  2. St. Vincent Medical Center, Department of Radiology (United States)

Percutaneous endovascular techniques were used to treat an arteriovenous fistula (AVF) associated with pancreatic transplantation. A pancreatic transplant superior mesenteric artery-to-superior mesenteric-vein AVF was successfully embolized while flow to the pancreas transplant was preserved. The embolization was aided by the use of Guglielmi detachable coils and a detachable balloon. No complications were encountered. At 23 months follow-up, the patient is doing well with no recurrence.