Image Quality and Radiation Dose Assessment of a Digital Mammography System
Journal Article
·
· AIP Conference Proceedings
- Department of Diagnostic Imaging, Hospital Putrajaya, Pres, 62250 Putrajaya, Walayah Persekutuan (Malaysia)
- Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)
Image quality and radiation dose of a direct amorphous selenium digital mammography system were considered in terms of contrast to noise ratio (CNR) and average glandular dose (AGD). They were measured for various qualities and breast phantom thicknesses with different types of breast tissue composition to determine optimal radiation quality and dose. Three sets of breast tissue equivalent slabs (30%:70%, 50%:50% and 70%:30% glandular-adipose) with thickness of 2 cm to 7 cm and 0.2 mm aluminum foil were used to provide certain CNR. Two different combinations of anode/ilter material and a wide range of tube voltages were employed for each phantom thickness. Phantom images with grid were acquired using automatic exposure control (AEC) mode for each thickness. Phantom images without grid were also obtained in manual exposure mode by selecting the same anode/filter combination and kVp as the image obtained with grid at the same thickness, but varying mAs of 10 to 200 mAs. Optimization indicated that relatively high energy beam qualities should be used with a greater dose to compensate for lower energy x-rays. The results also indicate that current AEC setting for a fixed detector is not optimal.
- OSTI ID:
- 21410542
- Journal Information:
- AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 1250; ISSN APCPCS; ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
TU-CD-207-04: Radiation Exposure Comparisons of CESM with 2D FFDM and 3D Tomosynthesis Mammography
A technique optimization protocol and the potential for dose reduction in digital mammography
Grid removal and impact on population dose in full-field digital mammography
Journal Article
·
Mon Jun 15 00:00:00 EDT 2015
· Medical Physics
·
OSTI ID:22565341
A technique optimization protocol and the potential for dose reduction in digital mammography
Journal Article
·
Mon Mar 15 00:00:00 EDT 2010
· Medical Physics
·
OSTI ID:22096658
Grid removal and impact on population dose in full-field digital mammography
Journal Article
·
Wed Feb 14 23:00:00 EST 2007
· Medical Physics
·
OSTI ID:20951048
Related Subjects
62 RADIOLOGY AND NUCLEAR MEDICINE
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
AMORPHOUS STATE
BEAMS
BIOMEDICAL RADIOGRAPHY
BODY
CHARGES
DIAGNOSTIC TECHNIQUES
DIMENSIONS
DOSES
ELECTRIC POTENTIAL
ELECTROMAGNETIC RADIATION
ELEMENTS
GLANDS
IMAGE PROCESSING
IMAGES
IONIZING RADIATIONS
MAMMARY GLANDS
MEDICINE
MOCKUP
NOISE
NUCLEAR MEDICINE
OPTIMIZATION
ORGANS
PHANTOMS
PROCESSING
RADIATION DOSES
RADIATION QUALITY
RADIATIONS
RADIOLOGY
SELENIUM
SEMIMETALS
STRUCTURAL MODELS
THICKNESS
X RADIATION
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
AMORPHOUS STATE
BEAMS
BIOMEDICAL RADIOGRAPHY
BODY
CHARGES
DIAGNOSTIC TECHNIQUES
DIMENSIONS
DOSES
ELECTRIC POTENTIAL
ELECTROMAGNETIC RADIATION
ELEMENTS
GLANDS
IMAGE PROCESSING
IMAGES
IONIZING RADIATIONS
MAMMARY GLANDS
MEDICINE
MOCKUP
NOISE
NUCLEAR MEDICINE
OPTIMIZATION
ORGANS
PHANTOMS
PROCESSING
RADIATION DOSES
RADIATION QUALITY
RADIATIONS
RADIOLOGY
SELENIUM
SEMIMETALS
STRUCTURAL MODELS
THICKNESS
X RADIATION