Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Development of a synthetic phase contrast imaging diagnostic

Journal Article · · Physics of Plasmas
DOI:https://doi.org/10.1063/1.3435217· OSTI ID:21378035
; ;  [1]
  1. Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)
A ''synthetic diagnostic'' has been developed to calculate the expected experimental response of phase contrast imaging (PCI), a scattering diagnostic used to measure density fluctuations in laboratory plasmas, to a tokamak discharge modeled with the GYRO nonlinear gyrokinetic code [J. Candy and R. Waltz, J. Comput. Phys. 186, 545 (2003)]. The synthetic PCI includes the spatial response of the experimental diagnostic, primarily implemented as a line integral of plasma density along the beam path, and the minimum and maximum wavenumber response resulting from the detection scheme. The synthetic PCI can be used for comparisons between GYRO and experiment as well as studies of the PCI response.
OSTI ID:
21378035
Journal Information:
Physics of Plasmas, Journal Name: Physics of Plasmas Journal Issue: 6 Vol. 17; ISSN PHPAEN; ISSN 1070-664X
Country of Publication:
United States
Language:
English