Multiplexing Readout of TES Microcalorimeters Based on Analog Baseband Feedback

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.3292397· OSTI ID:21325814
; ; ; ; ;  [1]; ;  [2]
  1. Institute of Space and Astronautical Science, 3-1-1 Yoshinodai, Sagamihara, 229-8510 Japan (Japan)
  2. SRON Netherlands Institute for Space Research, Sorbonnelaan 2, 3584CA Utrecht (Netherlands)

A TES microcalorimeter array is a promising spectrometer with excellent energy resolution and a moderate imaging capability. To realize a large format array in space, multiplexing the TES signals at the low tempersture stage is mandatory. We are developing frequency division multiplexing (FDM) based on baseband feedback technique. In FDM, each TES is AC-biased with a different carrier frequency. Signals from several pixels are summed and then read out by one SQUID. The maximum number of multiplexed pixels are limited by the frequency band in which the SQUID can be operated in a flux-locked loop, which is {approx}1 MHz with standard flux-locked loop circuit. In the baseband feedback, the signal ({approx}10 kHz band) from the TES is once demodulated. Then a reconstructed copy of the modulated signal with an appropriate phase is fed back to the SQUID input coil to maintain an approximately constant magnetic flux. This can be implemented even for large cable delays and automatically suppresses the carrier. We developed a prototype electronics for the baseband feedback based on an analog phase sensitive detector (PSD) and a multiplier. Combined with Seiko 80-SSA SQUID amp, open-loop gain of 8 has been obtained for 10 kHz baseband signal at 5 MHz carrier frequency, with a moderate noise contribution of 27pA/{radical}(Hz) at input.

OSTI ID:
21325814
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 1185; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Progress on Frequency-Domain Multiplexing Development for High Count rate X-ray Microcalorimeters
Journal Article · Tue Dec 15 23:00:00 EST 2009 · AIP Conference Proceedings · OSTI ID:21325796

Performance of an X-ray single pixel TES microcalorimeter under DC and AC biasing
Journal Article · Tue Dec 15 23:00:00 EST 2009 · AIP Conference Proceedings · OSTI ID:21325815

Frequency-Domain Multiplexed Readout for Superconducting Gamma-Ray Detectors
Journal Article · Wed Aug 30 00:00:00 EDT 2006 · IEEE Transactions on Applied Superconductivity · OSTI ID:937490