Title: One-point fitting of the flux density produced by a heliostat

Journal Article · · Solar Energy
 [1]
  1. Univ. Zaragoza, CPS-B, Dpto de Ingenieria Mecanica, Maria de Luna 3, 50018 Zaragoza (Spain)

Accurate and simple models for the flux density reflected by an isolated heliostat should be one of the basic tools for the design and optimization of solar power tower systems. In this work, the ability and the accuracy of the Universidad de Zaragoza (UNIZAR) and the DLR (HFCAL) flux density models to fit actual energetic spots are checked against heliostat energetic images measured at Plataforma Solar de Almeria (PSA). Both the fully analytic models are able to acceptably fit the spot with only one-point fitting, i.e., the measured maximum flux. As a practical validation of this one-point fitting, the intercept percentage of the measured images, i.e., the percentage of the energetic spot sent by the heliostat that gets the receiver surface, is compared with the intercept calculated through the UNIZAR and HFCAL models. As main conclusions, the UNIZAR and the HFCAL models could be quite appropriate tools for the design and optimization, provided the energetic images from the heliostats to be used in the collector field were previously analyzed. Also note that the HFCAL model is much simpler and slightly more accurate than the UNIZAR model. (author)

OSTI ID:
21305750
Journal Information:
Solar Energy, Vol. 84, Issue 4; Conference: International Conference CISBAT 2007; Other Information: Elsevier Ltd. All rights reserved; ISSN 0038-092X
Country of Publication:
United States
Language:
English