Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

An Interlaced IMRT Technique for Elongated Tumor Volumes

Journal Article · · Medical Dosimetry
 [1];  [1]; ; ; ; ;  [2]
  1. Department of Physics and Astronomy, University of Canterbury, Christchurch (New Zealand)
  2. Department of Radiation Oncology, University of Wuerzburg, Wuerzburg (Germany)

Treatment of large target volumes with intensity modulated radiotherapy (IMRT) can be restricted by the maximum field size of the multileaf collimator (MLC). In this work, a straightforward technique for MLC-based IMRT is presented, which is generally applicable and does not depend on the capabilities of the linear accelerator's IMRT delivery system. A dual isocenter technique was developed that maximizes beam overlap. The beams at the first isocenter are arranged such that they interlace with the beams at the second isocenter. All beams contribute to the overlap region, whereas only some contribute to the superior and some to the inferior part of the target. The interlaced technique (9 beams) was compared with an alternative more complex approach (14 beams) for a head-and-neck case with simultaneous integrated boost and 3 different dose levels. The plans were compared in terms of complexity, dosimetry, and the effect of inaccurate translation between the isocenters. The interlaced and the more complex IMRT technique resulted in nearly identical dose distributions without clinically relevant differences. The total number of monitor units (MUs) was comparable with more MUs per segment for the interlaced technique. For the interlaced technique, the number of segments {<=}5 MU was reduced by 43%. Simulation of isocenter setup errors of {+-}1, {+-}2, and {+-}3 mm revealed maximum dose point errors of 1.8%, 3.8%, and 5.4% in the target volume for the interlaced technique. The interlaced IMRT technique resulted in an equivalent plan to the more complex technique without compromising the dose distribution. The technique is less complex and is robust against inaccurate isocenter translations of up to {+-}1 mm. Due to the versatility of the technique, it can easily be applied to other anatomical regions and is well suited for clinical routine usage.

OSTI ID:
21286850
Journal Information:
Medical Dosimetry, Journal Name: Medical Dosimetry Journal Issue: 2 Vol. 34; ISSN 0958-3947; ISSN MEDOEJ
Country of Publication:
United States
Language:
English

Similar Records

Technical and Dosimetric Considerations in Multi-Isocenter Intensity Modulated Radiotherapy for Nasopharyngeal carcinoma with Small Multileaf Collimator
Journal Article · Wed Apr 01 00:00:00 EDT 2009 · Medical Dosimetry · OSTI ID:21180434

A dynamic supraclavicular field-matching technique for head-and-neck cancer patients treated with IMRT
Journal Article · Sun Oct 31 23:00:00 EST 2004 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20630950

The inter- and intrafraction reproducibilities of three common IMRT delivery techniques
Journal Article · Wed Sep 15 00:00:00 EDT 2010 · Medical Physics · OSTI ID:22098530