skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: An Evaluation of Two Internal Surrogates for Determining the Three-Dimensional Position of Peripheral Lung Tumors

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [2]; ; ;  [1]
  1. Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands)
  2. Department of Biostatistics, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands)

Purpose: Both carina and diaphragm positions have been used as surrogates during respiratory-gated radiotherapy. We studied the correlation of both surrogates with three-dimensional (3D) tumor position. Methods and Materials: A total of 59 repeat artifact-free four-dimensional (4D) computed tomography (CT) scans, acquired during uncoached breathing, were identified in 23 patients with Stage I lung cancer. Repeat scans were co-registered to the initial 4D CT scan, and tumor, carina, and ipsilateral diaphragm were manually contoured in all phases of each 4D CT data set. Correlation between positions of carina and diaphragm with 3D tumor position was studied by use of log-likelihood ratio statistics. Models to predict 3D tumor position from internal surrogates at end inspiration (EI) and end expiration (EE) were developed, and model accuracy was tested by calculating SDs of differences between predicted and actual tumor positions. Results: Motion of both the carina and diaphragm significantly correlated with tumor motion, but log-likelihood ratios indicated that the carina was more predictive for tumor position. When craniocaudal tumor position was predicted by use of craniocaudal carina positions, the SDs of the differences between the predicted and observed positions were 2.2 mm and 2.4 mm at EI and EE, respectively. The corresponding SDs derived with the diaphragm positions were 3.7 mm and 3.9 mm at EI and EE, respectively. Prediction errors in the other directions were comparable. Prediction accuracy was similar at EI and EE. Conclusions: The carina is a better surrogate of 3D tumor position than diaphragm position. Because residual prediction errors were observed in this analysis, additional studies will be performed using audio-coached scans.

OSTI ID:
21276846
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 74, Issue 2; Other Information: DOI: 10.1016/j.ijrobp.2009.01.003; PII: S0360-3016(09)00049-2; Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Analysis of Carina Position as Surrogate Marker for Delivering Phase-Gated Radiotherapy
Journal Article · Tue Jul 15 00:00:00 EDT 2008 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21276846

Impact of Audio-Coaching on the Position of Lung Tumors
Journal Article · Tue Jul 15 00:00:00 EDT 2008 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21276846

Renal mobility during uncoached quiet respiration: An analysis of 4DCT scans
Journal Article · Wed Mar 01 00:00:00 EST 2006 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21276846