Measurement of indoor air quality in two new test houses
This study assessed indoor air quality in two similar, new houses being evaluated for energy performance. One house (A) was built conventionally. The other (B) was an energy-efficient structure. Air samples for individual volatile organic compounds (VOCs), total VOCs (TVOC) and formaldehyde were collected following completion of the interiors of the houses and on several occasions during the following year. Ventilation rates were also determined so that source strengths of airborne contaminants could be estimated with a mass- balance model. There were no substantial differences in indoor air quality between the houses. The TVOC concentrations in House A ranged from 1,700 - 4,400 {mu}p m{sup -3}, with the highest value coinciding with the lowest ventilation rate. The TVOC concentrations in House B were 2,400 - 2,800 {mu}g m{sup -3}. These values are elevated compared to a median value of 700 {mu}g m{sup -3} measured for a large residential study. Formaldehyde concentrations ranged up to 74 {mu}g m{sup -3}. The dominant VOC in both houses was hexanal, an odorous chemical irritant. The concentrations of acetone, pentanal, toluene, alpha-pinene and other aldehydes were also relatively high in both houses. The source strengths of many of the analytes did not decline substantially over the course of the study. The OSB was estimated to contribute substantially to concentrations of formaldehyde and acetone in the houses. The results also suggested that OSB was not the dominant source of pentanal, hexanal and alpha-pinene, all of which had elevated emissions in the houses, possibly from a single source.
- Research Organization:
- Lawrence Berkeley Lab., CA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 212708
- Report Number(s):
- LBL--37929; ON: DE96008556
- Country of Publication:
- United States
- Language:
- English
Similar Records
Characterization of the Sources and Concentrations of Formaldehyde and other volatile organic compounds in four new manufactured houses
Volatile organic compound concentrations and emission rates measured over one year in a new manufactured house
Formaldehyde and acetaldehyde exposure mitigation in US residences: In-home measurements of ventilation control and source control
Conference
·
Tue Sep 01 00:00:00 EDT 1998
·
OSTI ID:6529
Volatile organic compound concentrations and emission rates measured over one year in a new manufactured house
Technical Report
·
Wed Sep 01 00:00:00 EDT 2004
·
OSTI ID:838617
Formaldehyde and acetaldehyde exposure mitigation in US residences: In-home measurements of ventilation control and source control
Technical Report
·
Wed Oct 01 00:00:00 EDT 2014
·
OSTI ID:1167387