Title: Diagnostic developments for quasicontinuous operation of the Wendelstein 7-X stellarator

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2964998· OSTI ID:21266653
; ; ; ; ; ; ; ; ; ; ; ; ; ;  [1]; ; ;  [2];  [3]
  1. Euratom Association, Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstr. 1, 17491 Greifswald (Germany)
  2. Euratom Association, KFKI-Research Institute for Particle and Nuclear Physics, H-1121 Budapest, Konkoly Thege 29-33 (Hungary)
  3. Department of Applied Mechanics, Euratom Association, Budapest University of Technology and Economics, P.O. Box 91, H-1521 Budapest (Hungary)

The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m{sup 2} from radiation alone and of up to about 500 kW/m{sup 2} on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m{sup 2} need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.

OSTI ID:
21266653
Journal Information:
Review of Scientific Instruments, Vol. 79, Issue 10; Conference: HTPD08: 17. topical conference on high-temperature plasma diagnostics, Albuquerque, NM (United States), 11-15 May 2008; Other Information: DOI: 10.1063/1.2964998; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

The Steady State Challenge for Soft X-Ray Diagnostics on Wendelstein 7-X Stellarator
Journal Article · Wed Mar 19 00:00:00 EDT 2008 · AIP Conference Proceedings · OSTI ID:21266653

Optical design study for divertor observation at the stellarator W7-X
Journal Article · Sun Oct 15 00:00:00 EDT 2006 · Review of Scientific Instruments · OSTI ID:21266653

The impact of microwave stray radiation to in-vessel diagnostic components
Journal Article · Thu Aug 21 00:00:00 EDT 2014 · AIP Conference Proceedings · OSTI ID:21266653