Title: Monte Carlo simulations of high-speed, time-gated microchannel-plate-based x-ray detectors: Saturation effects in dc and pulsed modes and detector dynamic range

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2969283· OSTI ID:21266573
; ;  [1];  [2]
  1. National Security Technologies, LLC, Los Alamos, New Mexico 87544 (United States)
  2. Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States)

We present here results of continued efforts to understand the performance of microchannel plate (MCP)-based, high-speed, gated, x-ray detectors. This work involves the continued improvement of a Monte Carlo simulation code to describe MCP performance coupled with experimental efforts to better characterize such detectors. Our goal is a quantitative description of MCP saturation behavior in both static and pulsed modes. A new model of charge buildup on the walls of the MCP channels is briefly described. The simulation results are compared to experimental data obtained with a short-pulse, high-intensity ultraviolet laser, and good agreement is found. These results indicate that a weak saturation can change the exponent of gain with voltage and that a strong saturation leads to a gain plateau. These results also demonstrate that the dynamic range of a MCP in pulsed mode has a value of between 10{sup 2} and 10{sup 3}.

OSTI ID:
21266573
Journal Information:
Review of Scientific Instruments, Vol. 79, Issue 10; Conference: HTPD08: 17. topical conference on high-temperature plasma diagnostics, Albuquerque, NM (United States), 11-15 May 2008; Other Information: DOI: 10.1063/1.2969283; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

Monte Carlo Simulations of High-Speed, Time-Gated MCP-based X-ray Detectors: Saturation Effects in DC Pulsed Modes and Detector Dynamic Range
Journal Article · Fri May 30 00:00:00 EDT 2008 · Monte Carlo Simulations of High-Speed, Time-Gated MCP-based X-ray Detectors: Saturation Effects in DC Pulsed Modes and Detector Dynamic Range · OSTI ID:21266573

Monte Carlo Simulations of High-speed, Time-gated MCP-based X-ray Detectors: Saturation Effects in DC and Pulsed Modes and Detector Dynamic Range
Conference · Fri Oct 31 00:00:00 EDT 2008 · Review of Scientific Instruments · OSTI ID:21266573

Monte Carlo Simulations of Microchannel Plate Detectors II: Pulsed Voltage Results
Journal Article · Fri Feb 11 00:00:00 EST 2011 · Review of Scientific Instruments · OSTI ID:21266573