Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Application of a digital pileup resolving method to high count rate neutron measurements

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2969278· OSTI ID:21266504
 [1]; ; ;  [2];  [3]
  1. ENEA, C.R. Frascati, Via E. Fermi, 45-Frascati, 00044 Roma (Italy)
  2. Associazione Euratom-ENEA sulla Fusione, C.R. Frascati, Via E. Fermi, 45-Frascati, 00044 Roma (Italy)
  3. Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig (Germany)
The possibility of working in high count rate conditions is an important issue for neutron measurements applied to fusion experiments in order to extend the measurement dynamic range and time resolution. One of the main issues of high count rate operation is the overlapping of closely spaced events (pileup) that produces a distortion in their amplitude and therefore in the pulse height spectra. The usual way to deal with such pileup events using standard analog electronics is to reject them in the energy analysis process. Thanks to digital acquisition techniques, the waveforms of pileup events can be recorded and elaborated in order to reconstruct the contributing original single events. This work presents the results of the application of a pileup resolving method for the reconstruction and analysis of overlapping events to pulses acquired digitally from a NE213 liquid scintillator detector. The measurements have been carried out at the PTB accelerator facility with 14 MeV neutrons at total count rates over 400 kHz.
OSTI ID:
21266504
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 10 Vol. 79; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English

Similar Records

Evaluation of a digital data acquisition system and optimization of n-{gamma} discrimination for a compact neutron spectrometer
Journal Article · Fri Jan 14 23:00:00 EST 2011 · Review of Scientific Instruments · OSTI ID:22062230

Accuracy in gamma spectrometry: Pileup, dead time, and fast electornics
Conference · Thu Dec 31 23:00:00 EST 1992 · Transactions of the American Nuclear Society; (United States) · OSTI ID:5780567

Comparison of pulse shape discrimination performance of stilbene and liquid scintillator under high count-rate active interrogation conditions
Journal Article · Sun Sep 16 20:00:00 EDT 2018 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1669215