Method to estimate the electron temperature and neutral density in a plasma from spectroscopic measurements using argon atom and ion collisional-radiative models
Journal Article
·
· Review of Scientific Instruments
- University of Texas at Austin, 1 University Station Austin, Texas 78712 (United States)
- West Virginia University, P.O. Box 6315, Morgantown, West Virginia 26506 (United States)
We present a method to infer the electron temperature in argon plasmas using a collisional-radiative model for argon ions and measurements of electron density to interpret absolutely calibrated spectroscopic measurements of argon ion (Ar II) line intensities. The neutral density, and hence the degree of ionization of this plasma, can then be estimated using argon atom (Ar I) line intensities and a collisional-radiative model for argon atoms. This method has been tested for plasmas generated on two different devices at the University of Texas at Austin: the helicon experiment and the helimak experiment. We present results that show good correlation with other measurements in the plasma.
- OSTI ID:
- 21266489
- Journal Information:
- Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 10 Vol. 79; ISSN 0034-6748; ISSN RSINAK
- Country of Publication:
- United States
- Language:
- English
Similar Records
Neutral argon density profile determination by comparison of spectroscopic measurements and a collisional-radiative model (invited)
On line-ratio analysis for helium-argon microwave discharges
Spectroscopic Characterization of Post-Cluster Argon Plasmas During the Blast Wave Expansion
Journal Article
·
Sun Oct 15 00:00:00 EDT 2006
· Review of Scientific Instruments
·
OSTI ID:20861334
On line-ratio analysis for helium-argon microwave discharges
Journal Article
·
Mon Feb 14 23:00:00 EST 2005
· Journal of Applied Physics
·
OSTI ID:20668188
Spectroscopic Characterization of Post-Cluster Argon Plasmas During the Blast Wave Expansion
Conference
·
Thu May 30 00:00:00 EDT 2002
·
OSTI ID:802837