Doppler spectroscopy of hydrogen Balmer lines in a hollow cathode glow discharge in ammonia and argon-ammonia mixture
- Faculty of Physics, 11001 Belgrade, P.O. Box 368 (Serbia)
The results of Doppler spectroscopy of hydrogen Balmer lines from a stainless steel (SS) and copper (Cu) hollow cathode (HC) glow discharge in ammonia and argon-ammonia mixture are reported. The experimental profiles in ammonia discharge are fitted well by superposing three Gaussian profiles. The half widths, in energy units, of narrow and medium Gaussians are in the ranges 0.3-0.4 eV and 3-4 eV, respectively, for both hollow cathodes what is expected on the basis of earlier electron beam{yields}NH{sub 3} experiments. The half widths of the largest Gaussian in ammonia are 46 and 55 eV for SS and Cu HC, respectively. In argon-ammonia discharge, three Gaussians are also required to fit experimental profiles. While half widths of narrow and medium Gaussians are similar to those in ammonia, the half widths of the largest Gaussians are 35 and 42 eV for SS and Cu HC, respectively. The half widths of the largest Gaussians in ammonia and in argon-ammonia mixture indicate the presence of excessive Doppler broadening.
- OSTI ID:
- 21259680
- Journal Information:
- Physics of Plasmas, Journal Name: Physics of Plasmas Journal Issue: 11 Vol. 15; ISSN PHPAEN; ISSN 1070-664X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Anomalous Broadening of Balmer H{sub {alpha}} Line in Aluminum and Copper Hollow Cathode Glow Discharges
Spectroscopic study of hydrogen Balmer lines in a microwave-induced discharge