First Results from The MAGNEX Large Acceptance Spectrometer

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.3039839· OSTI ID:21254813
; ; ; ; ;  [1];  [2]; ;  [3];  [4];  [5]
  1. INFN Laboratori Nazionali del Sud, Catania (Italy)
  2. Dipartimento di Fisica e Astronomia, Universita di Catania (Italy)
  3. IFUSP, Sao Paulo (Brazil)
  4. NIPNE, Bucharest (Romania)
  5. GSI, Darmstadt (Germany)
The MAGNEX large-acceptance spectrometer was commissioned with beams from the LNS Tandem. First results of physical interest are presented. The obtained 10{sup -3} energy resolution confirms the ambitious characteristic of the calculations and allows considering the instrument as an ideal tool for future studies in the field of nuclear spectroscopy and reaction mechanisms at incident energies not far form the Coulomb barrier.
OSTI ID:
21254813
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 1072; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English