A single-gap multi-harmonic buncher, developed in collaboration with Argonne National Laboratory, has been installed in the pre-acceleration region of NSC Pelletron. This buncher is required for injecting bunched beam into the booster LINAC, presently under construction. A saw-tooth voltage generated across a single gap formed by a closely spaced pair of grids is used for bunching the dc ion beam produced by the Pelletron accelerator. This saw-tooth voltage is produced by adding a sinewave with its three higher harmonics in proper phase and amplitude. {sup 28}Si beam has been bunched successfully using this buncher. The best FWHM of the bunched beam was 1.5ns and the maximum efficiency of bunching was 50%. The bunching voltage had no steering effect on the beam.
- OSTI ID:
- 21205464
- Journal Information:
- AIP Conference Proceedings, Vol. 473, Issue 1; Conference: 8. international conference on heavy-ion accelerator technology, Argonne, IL (United States), 5-9 Oct 1998; Other Information: DOI: 10.1063/1.58948; (c) 1999 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X