The DA{phi}NE beam position monitor (BPM) system consists of 150 monitors installed all along the machine. Design issues, calibration procedures, experimental results and performance of the system are described. The closed orbit in the main rings is extracted from the BPM signals through narrowband receivers (realized by Bergoz Precision Beam Instrumentation for DA{phi}NE), then acquired and processed by a real-time task based on four independent processors dealing with different machine areas. The data acquisition system is integrated in the DA{phi}NE control system and measures five complete orbits in a second. Implementation criteria, measurements and results are reported.