The SLAC E-154 {sup 3}He polarimeter

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.54965· OSTI ID:21182467
; ; ;  [1]; ; ; ;  [2];  [3];  [4];  [5]
  1. Princeton University, Princeton, New Jersey 08544 (United States)
  2. University of Michigan, Ann Arbor, Michigan 48109 (United States)
  3. California Institute of Technology, Pasadena, California 91125 (United States)
  4. University of Wisconsin, Madison, Wisconsin 53706 (United States)
  5. National Institute of Standards and Technology, Gainesville, Maryland 20899 (United States)
We describe the NMR and Rb Zeeman frequency shift polarimeters used for determining the {sup 3}He polarization in a recent precision measurement of the neutron spin structure function g{sub 1} at SLAC (E-154). We performed a detailed study of the systematic errors associated with the calibration of the NMR polarimeter. A new technique was used for determining the {sup 3}He polarization from the frequency shift of the Rb Zeeman resonance.
OSTI ID:
21182467
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 421; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English