Gated Irradiation With Scanned Particle Beams
Journal Article
·
· International Journal of Radiation Oncology, Biology and Physics
- Gesellschaft fuer Schwerionenforschung, Abt. Biophysik, Darmstadt (Germany)
Purpose: To demonstrate mitigation of the interplay effects of scanned particle beams and residual target motion within a gating window by increased overlap of pencil beams. Methods and Materials: Lateral overlap was increased by increasing the pencil beam widths or by decreasing the distance between the pencil beams (scan grid). Longitudinal overlap was increased by reducing the distance between iso-range slices. For scanned carbon ion beams, simulation studies were performed and validated experimentally to determine the required parameters for different residual motion characteristics. The dose distributions were characterized by the maximal local deviations representing local over- and underdosage. Results: For residual lateral motion, the local deviations were <5% for 2, 4, and 7 mm residual motion within the gating window for a 2-mm scan grid and pencil beams of 10, 14, and 18 mm full width at half maximum, respectively. Decreasing the iso-range slice distance from 3 mm to 1 mm effectively mitigated {<=}10 mm water-equivalent range changes. Experimental data reproduced the simulation results. Conclusion: In charged particle therapy with a scanned beam, interplay effects between gated beam delivery and residual target motion can be decreased effectively by increasing the overlap between pencil beams laterally, as well as longitudinally.
- OSTI ID:
- 21172693
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 4 Vol. 73; ISSN IOBPD3; ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
Respiratory motion management in particle therapy
TH-CD-209-07: Preliminary Experimental Comparison of Spot- and Continuous Line Scanning with Or Without Rescanning for Gated Proton Therapy
Moving target irradiation with fast rescanning and gating in particle therapy
Journal Article
·
Sun Feb 14 23:00:00 EST 2010
· Medical Physics
·
OSTI ID:22096618
TH-CD-209-07: Preliminary Experimental Comparison of Spot- and Continuous Line Scanning with Or Without Rescanning for Gated Proton Therapy
Journal Article
·
Wed Jun 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:22679334
Moving target irradiation with fast rescanning and gating in particle therapy
Journal Article
·
Wed Sep 15 00:00:00 EDT 2010
· Medical Physics
·
OSTI ID:22098532