Title: Seismic Vulnerability Evaluations Within The Structural And Functional Survey Activities Of The COM Bases In Italy

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2963797· OSTI ID:21148943
;  [1]; ; ; ; ; ;  [2]
  1. Studies Center Plinivs--Lupt, Univ. of Naples 'Federico II', Via Toledo 402--80134 Naples (Italy)
  2. Italian Department of Civil Protection, Via Vitorchiano 2, 00189, Rome (Italy)

The paper describes technical and functional surveys on COM buildings (Mixed Operative Centre). This activity started since 2005, with the contribution of both Italian Civil Protection Department and the Regions involved. The project aims to evaluate the efficiency of COM buildings, checking not only structural, architectonic and functional characteristics but also paying attention to surrounding real estate vulnerability, road network, railways, harbours, airports, area morphological and hydro-geological characteristics, hazardous activities, etc. The first survey was performed in eastern Sicily, before the European Civil Protection Exercise 'EUROSOT 2005'. Then, since 2006, a new survey campaign started in Abruzzo, Molise, Calabria and Puglia Regions. The more important issue of the activity was the vulnerability assessment. So this paper deals with a more refined vulnerability evaluation technique by means of the SAVE methodology, developed in the 1st task of SAVE project within the GNDT-DPC programme 2000-2002 (Zuccaro, 2005); the SAVE methodology has been already successfully employed in previous studies (i.e. school buildings intervention programme at national scale; list of strategic public buildings in Campania, Sicilia and Basilicata). In this paper, data elaborated by SAVE methodology are compared with expert evaluations derived from the direct inspections on COM buildings. This represents a useful exercise for the improvement either of the survey forms or of the methodology for the quick assessment of the vulnerability.

OSTI ID:
21148943
Journal Information:
AIP Conference Proceedings, Vol. 1020, Issue 1; Conference: 2008 seismic engineering conference: Commemorating the 1908 Messina and Reggio Calabria earthquake, Reggio Calabria (Italy), 8-11 Jul 2008; Other Information: DOI: 10.1063/1.2963797; (c) 2008 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Collapse Mechanisms Of Masonry Structures
Journal Article · Tue Jul 08 00:00:00 EDT 2008 · AIP Conference Proceedings · OSTI ID:21148943

Building Energy Efficiency in India: Compliance Evaluation of Energy Conservation Building Code
Technical Report · Wed Mar 26 00:00:00 EDT 2014 · OSTI ID:21148943

Seismic Risk Assessment of Italian Seaports Using GIS
Journal Article · Tue Jul 08 00:00:00 EDT 2008 · AIP Conference Proceedings · OSTI ID:21148943