Feasibility of IMRT to Cover Pelvic Nodes While Escalating the Dose to the Prostate Gland: Dosimetric Data on 35 Consecutive Patients

Journal Article · · Medical Dosimetry
 [1];  [2];  [1];  [2]
  1. Department of Medical Physics, University of Texas Medical Branch, Galveston, TX (United States)
  2. Department of Radiation Oncology, University of Texas Medical Branch, Galveston, TX (United States)

Utilizing available dosimetric and acute toxicity data, we confirm the feasibility of intensity modulated radiotherapy (IMRT) to include treatment of the pelvic nodes (PN) while escalating the dose to the prostate. Data were obtained from 35 consecutive patients with prostate cancer with {>=}15% risk of PN involvement. Patients received an initial boost to the prostate, delivering 16 Gy over 8 fractions using a 6-field conformal technique, followed by an 8-field coplanar inverse planning IMRT technique delivering an additional 60 Gy over 30 fractions to the prostate (76 Gy total) and 54 Gy over 30 fractions to the seminal vesicles (SV) and PN. Dose-volume histogram analysis was performed for planning target volumes and organs at risk. Acute toxicity (RTOG/EORTC scale) was prospectively and independently scored weekly for each patient. The maximum, mean, minimum dose, and D95 to each planning target volume is provided: prostate (82.2, 78.2, 72.6, 75.2 Gy), SV (79.0, 72.5, 56.9, 61.1 Gy), and PN (80.4, 59.7, 46.5, 53.3 Gy), respectively. The percent volume receiving a dose at or above 'x' Gy (Vx) was recorded for V75, V70, V65, V60, and V50 as: bladder (14%, 24%, 32%, 39%, and 54%) and rectum (3%, 18%, 26%, 34%, and 51%), respectively. Acute toxicity was as follows: 54% grade 2+ GI (n = 19), 25% grade 2+ GU (n = 9). IMRT enables treatment of pelvic nodes while escalating dose to the prostate and is clinically feasible with acute toxicity within expected ranges.

OSTI ID:
21140785
Journal Information:
Medical Dosimetry, Journal Name: Medical Dosimetry Journal Issue: 3 Vol. 33; ISSN 0958-3947; ISSN MEDOEJ
Country of Publication:
United States
Language:
English

Similar Records

Clinical Application of High-Dose, Image-Guided Intensity-Modulated Radiotherapy in High-Risk Prostate Cancer
Journal Article · Tue Jun 01 00:00:00 EDT 2010 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21372296

Is IMRT needed to spare the rectum when pelvic lymph nodes are part of the initial treatment volume for prostate cancer?
Journal Article · Sat Dec 31 23:00:00 EST 2005 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20788279

Acute Toxicity in High-Risk Prostate Cancer Patients Treated With Androgen Suppression and Hypofractionated Intensity-Modulated Radiotherapy
Journal Article · Thu Jan 14 23:00:00 EST 2010 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21367585