Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Analysis of instantaneous profile test data from soils near the Mixed Waste Landfill, Technical Area 3, Sandia National Laboratories/New Mexico

Technical Report ·
DOI:https://doi.org/10.2172/211334· OSTI ID:211334
;  [1]; ;  [2]
  1. GRAM, Inc., Albuquerque, NM (United States)
  2. Sandia National Labs., Albuquerque, NM (United States)
This paper presents the results of an instantaneous profile test conducted near the Mixed Waste Landfill at Sandia National Laboratories/New Mexico. The purpose of the test was to measure the unsaturated hydraulic properties of soils near the Mixed Waste Landfill, including the relations between hydraulic conductivity, moisture content, and soil water tension. A 4.7 meter by 4.7 meter plot was saturated with water to a depth of 2 meters, and the wetting and drying responses of the vertical profile were observed. These data were analyzed to obtain in situ measurements of the unsaturated hydraulic properties.
Research Organization:
Sandia National Labs., Albuquerque, NM (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
211334
Report Number(s):
SAND--95-1637; ON: DE96008037
Country of Publication:
United States
Language:
English