Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A device for calibrating Rogowski coils in time domain

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.2972153· OSTI ID:21124124
; ;  [1]
  1. School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049 (China)
In this article a device for calibrating Rogowski coils in time domain is designed, which can obtain the sensitivity and dynamic response of the Rogowski coil by means of measuring currents of long pulse durations and few nanoseconds rise time. Its key device is a current step wave generator, which can generate the output with rise time of <3 ns and with duration time of >300 ns.
OSTI ID:
21124124
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 8 Vol. 79; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English