Dosimetric characterization of CyberKnife radiosurgical photon beams using polymer gels
- Medical Physics Department, Iatropolis - Magnitiki Tomografia Clinic and Diagnostic Center, Ethnikis Antistaseos 54-56, Chalandri, 152 31, Athens (Greece)
Dose distributions registered in water equivalent, polymer gel dosimeters were used to measure the output factors and off-axis profiles of the radiosurgical photon beams employed for CyberKnife radiosurgery. Corresponding measurements were also performed using a shielded silicon diode commonly employed for CyberKnife commissioning, the PinPoint ion chamber, and Gafchromic EBT films, for reasons of comparison. Polymer gel results of this work for the output factors of the 5, 7.5, and 10 mm diameter beams are (0.702{+-}0.029), (0.872{+-}0.039), and (0.929{+-}0.041), respectively. Comparison of polymer gel and diode measurements shows that the latter overestimate output factors of the two small beams (5% for the 5 mm beam and 3% for the 7.5 mm beams). This is attributed to the nonwater equivalence of the high atomic number silicon material of the diode detector. On the other hand, the PinPoint chamber is found to underestimate output factors up to 10% for the 5 mm beam due to volume averaging effects. Polymer gel and EBT film output factor results are found in close agreement for all beam sizes, emphasizing the importance of water equivalence and fine detector sensitive volume for small field dosimetry. Relative off-axis profile results are in good agreement for all dosimeters used in this work, with noticeable differences observed only in the PinPoint estimate of the 80%-20% penumbra width, which is relatively overestimated.
- OSTI ID:
- 21120751
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 35; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluation of GAFCHROMIC registered EBT film for CyberKnife registered dosimetry
Relative output factor measurements of a 5 mm diameter radiosurgical photon beam using polymer gel dosimetry
Monte Carlo study of a Cyberknife stereotactic radiosurgery system
Journal Article
·
Fri Jun 15 00:00:00 EDT 2007
· Medical Physics
·
OSTI ID:20951487
Relative output factor measurements of a 5 mm diameter radiosurgical photon beam using polymer gel dosimetry
Journal Article
·
Wed Jun 15 00:00:00 EDT 2005
· Medical Physics
·
OSTI ID:20726051
Monte Carlo study of a Cyberknife stereotactic radiosurgery system
Journal Article
·
Tue Aug 15 00:00:00 EDT 2006
· Medical Physics
·
OSTI ID:20853396