Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Comments on shielding for dual energy accelerators

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2911158· OSTI ID:21120745
; ; ;  [1]
  1. Radiation Oncology, Hartford Hospital, 80 Seymour Street, Hartford, Connecticut 06102 (United States)

Determination of shielding requirements for medical linear accelerators has been greatly facilitated by the publication of the National Council on Radiation Protection and Measurements (NCRP) latest guidelines on this subject in NCRP Report No. 151. In the present report the authors review their own recent experience with patient treatments on conventional dual energy linear accelerators to examine the various input parameters needed to follow the NCRP guidelines. Some discussion is included of workloads, occupancy, use factors, and field size, with the effects of intensity modulated radiotherapy (IMRT) treatments included. Studies of collimator settings showed average values of 13.1x16.2 cm{sup 2} for 6 MV and 14.1x16.8 cm{sup 2} for 18 MV conventional ports, and corresponding average unblocked areas of 228 and 254 cm{sup 2}, respectively. With an average of 77% of the field area unblocked, this gives a mean irradiated area of 196 cm{sup 2} for the 18 MV beam, which dominates shielding considerations for most dual energy machines. Assuming conservatively small room dimensions, a gantry bin angle of 18 deg. was found to represent a reasonable unit for tabulation of use factors. For conventional 18 MV treatments it was found that the usual treatment angles of 0, 90, 180, and 270 deg. were still favored, and use factors of 0.25 represent reasonable estimates for these beams. As expected, the IMRT fields (all at 6 MV) showed a high degree of gantry angle randomization, with no bin having a use factor in excess of 0.10. It is concluded that unless a significant number of patients are treated with high energy IMRT, the traditional use factors of 0.25 are appropriate for the dominant high energy beam.

OSTI ID:
21120745
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 35; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Poster – 12: Radiological assessment of the secondary barrier shielding for IMRT treatments delivered through patient inhomogeneities
Journal Article · Mon Aug 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:22689320

Limited Advantages of Intensity-Modulated Radiotherapy Over 3D Conformal Radiation Therapy in the Adjuvant Management of Gastric Cancer
Journal Article · Mon Jun 01 00:00:00 EDT 2009 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21276838

Feasibility study of beam orientation class-solutions for prostate IMRT
Journal Article · Fri Oct 01 00:00:00 EDT 2004 · Medical Physics · OSTI ID:20634604