Unifying dose specification between clinical BNCT centers in the Americas

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2884856· OSTI ID:21120639
; ; ; ; ; ; ; ;  [1]
  1. Nuclear Reactor Laboratory, Massachusetts Institute of Technology, 138 Albany Street, Cambridge, Massachusetts 02139 (United States)
A dosimetry intercomparison between the boron neutron capture therapy groups of the Massachusetts Institute of Technology (MIT) and the Comision Nacional de Energia Atomica (CNEA), Argentina was performed to enable combined analyses of NCT patient data between the different centers. In-air and dose versus depth measurements in a rectangular water phantom were performed at the hyperthermal neutron beam facility of the RA-6 reactor, Bariloche. Calculated dose profiles from the CNEA treatment planning system NCTPlan that were calibrated against in-house measurements required normalizations of 1.0 (thermal neutrons), 1.13 (photons), and 0.74 (fast neutrons) to match the dosimetry of MIT.
OSTI ID:
21120639
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 4 Vol. 35; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Treatment of Spent Argentine Ion Exchange Resin Using Vitrification - Results of FY01 Testing at the Savannah River Technology Center
Technical Report · Wed Aug 14 00:00:00 EDT 2002 · OSTI ID:799745

Argentina`s nuclear industry
Journal Article · Sun Jan 31 23:00:00 EST 1988 · NUEXCO. Monthly Report to the Nuclear Industry · OSTI ID:104831

Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments
Journal Article · Wed Dec 14 23:00:00 EST 2011 · Medical Physics · OSTI ID:22100620