Determination of total mercury in sorbent tubes using direct mercury analysis

Journal Article · · American Laboratory
OSTI ID:21116455
 [1]
  1. Milestone Inc., Shelton, CT (United States)
A U.S. EPA draft method, Method 30 B, has been approved as a reference method for relative accuracy testing audits of Continuous Emissions Monitoring Systems (CEMS) and sorbent trap monitoring systems installed at coal-fired utilities. It is also appropriate for mercury emissions testing at such facilities. This method is a procedure for measuring total vapor phase mercury emissions from coal-fired combustion sources using all extractive or thermal analytical technique and UV atomic absorption (AA) or UV atomic fluorescence (AF) cold vapor analyzers as the analytical system. The DMA-80 direct mercury analyzer uses thermal decomposition and ultimately AA spectrophotometry to analyze samples. The analyzer can be used for Method 30 B analysis.
OSTI ID:
21116455
Journal Information:
American Laboratory, Journal Name: American Laboratory Journal Issue: 14 Vol. 40; ISSN ALBYBL; ISSN 0044-7749
Country of Publication:
United States
Language:
English

Similar Records

Novel sorbents for mercury removal from flue gas
Conference · Thu Jul 01 00:00:00 EDT 1999 · OSTI ID:20082302

Novel sorbents for mercury removal from flue gas
Journal Article · Fri Mar 31 23:00:00 EST 2000 · Industrial and Engineering Chemistry Research · OSTI ID:20062644

Evaluation of continuous monitors for mercury measurements in pilot-scale tests
Conference · Wed Dec 30 23:00:00 EST 1998 · OSTI ID:679329