Comparison of traditional nondestructive analysis of RERTR fuel plates with digital radiographic techniques
The current design and fabrication process for RERTR fuel plates utilizes film radiography during the nondestructive testing and characterization. Digital radiographic methods offer a potential increases in efficiency and accuracy. The traditional and digital radiographic methods are described and demonstrated on a fuel plate constructed with and average of 51% by volume fuel using the dispersion method. Fuel loading data from each method is analyzed and compared to a third baseline method to assess accuracy. The new digital method is shown to be more accurate, save hours of work, and provide additional information not easily available in the traditional method. Additional possible improvements suggested by the new digital method are also raised. (author)
- Research Organization:
- Argonne National Laboratory, Nuclear Engineering Division, RERTR Department, Argonne, IL (United States); Czech Technical University, Prague (Czech Republic)
- OSTI ID:
- 21113488
- Report Number(s):
- INIS-US-08N0001; TRN: US08N0010121026
- Resource Relation:
- Conference: RERTR-2007: 29. international meeting on reduced enrichment for research and test reactors, Prague (Czech Republic), 23-27 Sep 2007; Other Information: Country of input: International Atomic Energy Agency (IAEA); 5 refs, 6 figs, 4 tabs; Related Information: In: 2007 international meeting on Reduced Enrichment for Research and Test Reactors (RERTR). Abstracts and available papers presented at the meeting, vp.
- Country of Publication:
- United States
- Language:
- English
Similar Records
TESTING AND ACCEPTANCE OF FUEL PLATES FOR RERTR FUEL DEVELOPMENT EXPERIMENTS
Uses of x-ray radiographic and tomographic methods for nondestructive evaluation (NDE) of waste